  "description": "Interior framing is typically anchored to the slab or attached via engineered non-rigid clips; never cut or drill into primary rigid frames without engineering",
  "url": "https://totalbuildingsystems.net/faq/can-interior-walls-and-ceilings-be-attached-directly-to-the-metal-building-frame",
  "mainEntity": [
    {
      "@type": "Question",
      "name": "Can interior walls and ceilings be attached directly to the metal building frame?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "Cutting or drilling into primary structural frames or rigid rafters is generally prohibited, as it compromises the engineered load capacity of the building shell. Pre-engineered steel buildings are designed to carry specific live, dead, wind, and seismic loads. Instead of altering primary frames, contractors attach interior walls using light-gauge tracks secured to the concrete slab, floating clips on secondary purlins, or self-supporting ceiling joist systems. If you must hang heavy mechanical units or build a mezzanine, an engineer must review the framing plans to verify whether reinforcement or dedicated posts are necessary.",